Comparison of Short-term Breathing Rate Asymmetry of Preeclamptic and Normotensive Women at Labor
Comparison of Short-term Breathing Rate Asymmetry of Preeclamptic and Normotensive Women at Labor
dc.audience | researchers | |
dc.audience | teachers | |
dc.audience | students | |
dc.audience | other | |
dc.contributor.author | Ana Karen Talavera Peña , 0009-0003-3256-4388 | |
dc.contributor.author | Eric Alonso Abarca-Castro, 0000-0002-2029-3790 | |
dc.contributor.author | Hugo Mendieta Zeron, 0000-0003-3492-8950 | |
dc.contributor.author | Laura Mercedes Santiago-Fuentes, 0000-0003-2171-518X | |
dc.contributor.author | José Javier Reyes-Lagos, 0000-0001-5361-5007 | |
dc.contributor.author | Ximena Gonzalez Reyes, 0009-0001-3003-0126 | |
dc.coverage | MX | |
dc.date.accessioned | 2024-05-22T22:43:21Z | |
dc.date.available | 2024-05-22T22:43:21Z | |
dc.date.issued | 2024 | |
dc.description | This dataset contains breath-to-breath (BB) interval signals in milliseconds, captured from parturient women at the "Mónica Pretelini Saenz" Maternal-Perinatal Hospital in Toluca de Lerdo, State of Mexico, during 2021-2022. The dataset includes signals from three distinct groups: normotensive control (C), moderate pre-eclampsia (P), and severe pre-eclampsia (SP), corresponding to different stages of pregnancy and blood pressure levels. Each signal was recorded with a sampling frequency of 1000 Hz using a Mobi mobile amplifier system equipped with a respiration sensor. The pre-processing steps applied to the respirograms involved band-pass filtering within 0.2 to 0.5 Hz to isolate the breath-to-breath intervals, followed by peak detection and manual selection of reliable five-minute BB interval segments. Additionally, an adaptive filter was used to remove artifacts, enhancing the integrity and accuracy of the BB interval. | |
dc.format | application/zip | |
dc.identificador.materia | 3 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12222/429 | |
dc.language | eng | |
dc.publisher | Universidad Autónoma Metropolitana. Unidad Lerma | |
dc.rights.license | info:eu-repo/semantics/openAccess | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | MEDICINA Y CIENCIAS DE LA SALUD | |
dc.subject.keywords | Pre-Eclampsia | |
dc.subject.keywords | Respiratory rate variability | |
dc.subject.keywords | Breathing Rate Asymmetry | |
dc.subject.keywords | Autonomic activity | |
dc.subject.keywords | Pregnancy | |
dc.title | Comparison of Short-term Breathing Rate Asymmetry of Preeclamptic and Normotensive Women at Labor | |
dc.type | lecture | |
dc.type.version | info:eu-repo/semantics/acceptedVersion |